The electrical and mechanical tests are made according to technical standards, to customers’ requests and to TI.CA.’s data sheets and are constantly carried out on the daily production.

The final tests, besides, when required, can make in the laboratory in co-operation with the customers.

The laboratory equipment is regularly checked and calibrated by primary approved and certified samples from the main domestic trustworthy centers (SIT).

The TI.CA. technical tests generally include:

  • ageing in climate cold and hot cooms;
  • tension;
  • fire resistance;
  • insulation resistance;
  • electrical resistance of the conductor (Ohm/Km);
  • flame resistance;
  • dielectric strength;
  • resistance to break-down;
  • impedance;
  • capacitance;
  • inductance
  • attenuation;
  • resistance tests inside a chain cable holder;
  • any further special tests according to customer’s request.

SPECIAL CABLES

The company TI.CA. srl Special Cables, located in Tirano (SO) 2 km from Swizterland, produces special cables for more than 30 years and it is a consolidated professional reality in the national as well as international market.

readmore en_a

LABORATORY

The electrical and mechanical tests are made according to technical standards, to customers’ requests and to TI.CA.’s data sheets and

are constantly carried out on the daily production.

readmore en_a

WATCH THE VIDEO